Full cable tray and cable management nema catalog eaton. Cable tray numbering system contd a l u m i n u m fitting pre. Metsec cable trays generally conform to bs en 61537. Tray cables do not provide internal moisture paths as do. Metsec offer complete cable tray systems from 12mm to 50mm deep and 50mm to 900mm wide, all with a wide range of accessories. How to size a cable correctly stepbystep comprehensive. This stage of design converts process requirements into actual hardware. The cable tray sizing equals the width times the loading depth. Practices for grounding and bonding of cable trays photo credit. In applications where multiple motors are each powered by a separate vfd, care must be taken regarding the selection of the inverter to motor cables.
Download now for a product quick selection guide and overview of the offering. Eaton s submittal builder tool for bline series cable ladder and tray allows you to easily filter, select and download straight section, fitting and accessory submittals. Per the national electrical code article nema 3929b cable tray fill calculations and cable tray sizing calculations will be computed as follows. It provides the needed flexibility in circuit layouts in. Cable tray systems and standards cable management metsec. Download free excel program for cable sizing calculation. Cable trays may be filled 50% when using control or signal wiring. Cable tray fill calculator cable tray sizing mp husky. Cable tray fill and sizing volts electrical design software. All metallic cable trays shall be grounded as required in article 250. These guidelines will be particularly useful for the design, specification, procurement, installation and maintenance of these systems. Technical and sizing data unitray cable tray systems. All data used in this excel sheet are according to iee. Wire mesh cable tray fill ratio fill ratio cross section of cable cross section of tray according to nec 392.
Sizing cable sizing methods follow the unchanged basic step process. Calculate size of cable tray excel sheet electrical. Cable tray systems are most often supplied without covers and therefore lack the security that a well designed cable bus systems will provide. Abbbailey foundation fieldbussee protocol listings on page 8. The sum of the cross sectional areas of all cables cannot exceed 50% of the trays fill area. The final drawings for a cable tray wiring system may be completed and sent out for bid or construction more quickly than for a conduit wiring system.
Cable tray should be perforated and 20% spare capacity. Excel containment sizing calculator excel networking. The spreadsheet calculates cable size according to length, amperage, temperature and number group cables. Cable tray and tray cable are also less susceptible to fire loss than conduit. The last number is the length of the cable tray in meters or inches. The primary role of cablofil cable management from legrand is to be an efficient and universal cable support. A small amount of engineering is required to change the width of a cable tray to gain additional wiring space capacity. Few designers go into the design detail necessary to reduce the effects of moisture in the conduit systems. Cable tray wiring systems are the preferred wiring system when they are evaluated against equivalent conduit wiring systems in terms of safety, dependability, space and cost. Cable trays are available in different sizes as per the customer specifications. Since then, demand for wire cable tray has expanded rapidly and in 2001, cablofil demonstrated its commitment to the north american electrical market by establishing a 78,000 sq. The unique unistrut aluminium system splice plate is close fitting so that it is retained neatly and firmly on the cable ladder side rail. Wire basket cable tray fill calculator cable tray sizing calculator. A combination of conduits, cable trays, support hooks, tie wraps, and.
Pdf effective cable sizing model for building electrical. Change is a complex problem when conduit banks are involved. Materials and finishes available are mild steel pre galvanised as standard with mild steel hot dip galvanisedafter manufacture and stainless steel grade 1. A very informative and graphical report can be obtained after the analysis calculation is accomplished. In this series of videos about cable tray systems, you will know the usage of the cable tray systems in projects, its different types, the methods of cable trays installation, the calculations. Extruded aluminum ensure smooth edges, providing protection for cables.
Additionally, the entered cable conductor information can be saved. Special rung design to accommodate stainless steel banding of cables. Download also cable tray and conduit sizing excel sheet. Calculate size of cable tray for following cable schedule. Cable trays sizing according to egyptian code youtube. Best practice guide to cable ladder and cable tray systems. Three cable ladder series are available to help optimize design and lower total installed cost. Best practice guide to cable ladder and cable tray. Bline has recognized the need for a complete cable tray reference source for electrical engineers and designers. Full guide of cable tray installation and sizing part 1. The metal in cable trays may be used as the egc as per the limitations of table 392. A length of installed media in between connection points, which may include permanent splices.
We manufacture cable trays in the following thicknesses 1. Cable trays, gi perforated cable trays, manufacturer. Cable selection is even more critical if the cables are to be run any distance together in a raceway. Article 392 i no of multi core cables less than 2000 volts in the cable tray a 40 awgkcmil 120 sq.
An external fire usually results in damage to only a few feet of a cable tray system, while wire insulation inside a conduit suffers significant damage and thermoplastic insulation may actually fuse to the conduit. Cable tray must be supported on spans shorter than or equal to the length of the cable tray being installed. Calculate cable tray width calculate cable tray area calculate cable tray length calculate cable tray weight calculate remaining % width of cable tray calculate remaining % area of cable tray free download. Complete cable tray manual for electrical engineers and. This article will be a good reference guide for how to size a cable, and we will also include a pdf version. Cable support solutions cable ladders, tray and supports css. Tray columns are widely used in various types of mass transfer operations. An effective cable sizing procedure model for industries an d commerial buildings dr. How to size a cable, conductor sizing per the nec national electrical code experts in the usa. Special bracketryis designed for various brands of products to be supported in this fashion. Description the sheet works with a series of input data giving you a number of calculated values. For technical queries with regards to your warranty application please.
Everything that is required for the system is supplied. However it is often necessary to select a tray or ladder design in the absence of accurate information on the likely cable load. A covering over the optical fiber or conductor assembly that may include one or more metallic members, strength members, or jackets. We wrote this article because every single day we are asked by electrical engineers, electrical contractors, and others in the electrical construction field about how to size a cable.
Tray must have an inside available width equal to or greater than the sum of the diameters of the cables, which installed in a single layer. Complete systemmdf cable bus is sold as a complete electrical feeder system. Once the process design stage ends, the equipment design begins. In addition to the enclosure, the system also includes cables. The mechanical performance of all products and accessories is tested to the stringent requirements of the international standard iec 61537 and nema ve1csa 22. Find product information quickly and easily with the 2016 17 cablofil. Firstly, its vital firstly, its vital to gather data about the cables, installation surr oundings, and the load that it. To properly evaluate a cable tray wiring system vs. The bline cable tray manual was produced by blines technical staff. Individual rungs will support without collapse a 200 lb. Cable tray size as per national electrical code free download as word doc. Nithiyananthan 38 figure 2 shows rating factors to be included for m ore than one circuit and cables. Chart is based on 50% fill of 4 utp category 6 cable o.
One of the most prominent hardwares used for mass transfer is tray. Spare capacity of 10 % is considered for cable trays as per design philosophy for electrical. Cable tray size as per national electrical code2002. The ladder cable tray must have an inside available width equal to or greater than the sum of the diameters. Select nominal depth and width of tray based on cable loading. Number of multiconductor cables rated 2000 volts or less. Select the bottom type based on cables and spacing requirements. Cable support systems in the international world it is not uncommon to use either the cable tray or ladder to be used as a means to directly mount lighting fixtures to the support structure. Generally, cable tray sizing is correct when it appears 50% full of cable or wire, or when it contains a 50% fill of cables or wire. Learn more about the newest addition to the cablofil cable tray products. Cable tray size as per national electrical code manufactured.
1416 589 713 321 14 656 1447 1039 254 1429 600 621 1217 603 1288 1435 222 999 218 125 657 1211 270 1176 329 369 1428 1201 947 1143 1299 1032 1195